Thermal Imaging
Thermal Imaging is very important for commercial sites. It gives a real time view of the equipment’s operating temperature. This gives an operator a good idea of the condition of the pump.
Combining thermal imaging into you regular maintenance schedule will increase pump life and greatly reduce the chance of premature failure.
Pump 2 is running 7 degrees hotter than pump 1. This indicated excess bearing wear in pump 2. This temperature difference could not have been picked up by the old fashioned “look, listen, feel” technique.
The motor for this pump is running at a relatively good temp. The pump is temperature excellent.
The worn out bearings in the electric motor that was driving a pump, had overheated so badly that it created a very dangerous hot spot in the electrical circuits operating the motor.
The pump was immediately isolated and on further inspection it was revealed the the contactor from the heat, had welded its self together creating a constant open circuit that could not be tripped by the thermal overload.
This situation could have sparked an electrical fire and would not have been picked up without thermal imaging being added to the sites maintenance schedule.
Pool 50m Filtration Pump and Motor
A swimming centre in the country had some issues with the 50m recirculation pump and motor. The pump and motor were quite old and needed some repairs and up grades.
They looked at the expensive option of replacing the pump but due to budget restraints it was preferred to overhaul the existing pump and motor.
One of the major problems was the constant leaking water from the gland packing. Chlorinated water is very corrosive and it was causing reasonable damage to the pump housing and base.
It was essential to re-engineer the pump and replace the gland packing with a mechanical seal.
Cold water pump replacement, motor overhaul and laser alignment.
We were called in to overhaul the pump and motor but when the pump was being pulled down, we saw major damage to the impeller and shaft. It was decided to replace the pump.
Pool filtration pump overhaul and backing plate replacement
This pool filtration pump had a badly worn backing plate caused by cavitation. The pump is a close coupled motor so we replaced the motor bearings as well as the backing plate and mechanical seal.
Heat Booster Pump Overhaul
Last week we overhauled and laser aligned the heat booster pumps and motors for a inner city hotel.